ENplus A1 is the highest quality class of wood pellets in the scheme run by the European Pellet Council — the fuel must meet all parameters of EN ISO 17225-2 for class A1 simultaneously (including ash ≤0.7%, net calorific value ≥16.5 MJ/kg, mechanical durability ≥97.5%), and the producer is obliged to maintain constant process control and testing, documented in the plant specification. The class is "all-inclusive": one parameter outside the limit means the batch is not A1, regardless of the other results.
Key takeaways:
- All class A1 parameters must be met simultaneously — the class is a package, not a pick-and-choose;
- Most exceedances originate in the raw material (ash, chlorides, sulphur) and at the press (durability, density);
- In-house process tests plus tests in an accredited laboratory must be documented in the plant specification;
- An exceedance triggers the nonconforming product procedure: quarantine, retesting, root cause analysis, reclassification;
- We state values according to public editions of standards and the handbook — check the current edition of the scheme documents before the audit.
Table of contents
Where the ENplus A1 requirements come from
The quality parameters of class A1 have two sources. The first is the EN ISO 17225-2 standard (solid fuels — industrial and commercial grade wood pellets), which defines classes A1, A2 and B and the test methods from the EN ISO 18122, 18125 and 17831 series. The second source is the ENplus handbook (ST 1001) — a scheme document that refers to the standard while tightening some requirements and adding organisational elements: the plant specification, in-house testing, labelling and batch traceability. In certification practice, what is binding is what you enter in the plant specification approved by the certification body — and it is against that document that the auditor will compare your production records.
It is worth remembering that ENplus certifies not only the product, but also the producer's quality management system. That is why, besides test results, the audit covers raw material documentation, supervision of measuring equipment, training and the handling of nonconforming product.
Class A1 parameter table
Below are the key class A1 parameters under EN ISO 17225-2 and the ENplus handbook (indicative values — the current edition of the scheme document is binding):
| Parameter | A1 requirement | Main source of risk |
|---|---|---|
| Ash content | ≤ 0.7% (dry basis) | Bark, sand and mineral contamination of the raw material |
| Net calorific value (NCV) | ≥ 16.5 MJ/kg as received | Excessive product moisture, ash share |
| Mechanical durability | ≥ 97.5% | Moisture before the press, die condition, cooling |
| Fines (<3.15 mm) | ≤ 1.0% | Poor screening, mechanical conveying |
| Bulk density | ≥ 600 kg/m³ | Under-compacted pellets, wrong press settings |
| Diameter | 6 mm or 8 mm (± 1 mm) | Die — the declared size must match |
| Length | 3.15–40 mm | Cutter knife settings, breakage |
| Moisture | ≤ 10% | Drying, condensation in storage and transport |
| Nitrogen | ≤ 0.3% (dry basis) | Bark, green plant parts in the raw material |
| Chlorides (Cl) | ≤ 0.02% (dry basis) | Contaminated raw material, treated (impregnated) wood |
| Sulphur (S) | ≤ 0.04% (dry basis) | Contaminated raw material |
| Ash deformation temperature | declared (indicatively ≥ 1200 °C) | Mineral composition of the raw material |
| Heavy metals (As, Cd, Cr, Cu, Pb, Hg, Ni, Zn) | limits per the standard, tested at certification | Waste wood, paints, preservatives |
The scheme also allows pressing aids (e.g. starch-based) in a limited amount — indicatively up to 2% by mass — provided they are disclosed in the documentation and comply with the standard's requirements on permitted aid types.
How to control parameters in production
Ash — the decision is made at the raw material stage
Ash cannot be "fixed" in the process — it is a parameter you acquire together with the raw material. Control it at intake: qualify suppliers, test the ash of raw material batches periodically and physically limit contamination (reloading with a bucket on concrete instead of bare ground, a stone separator, a magnet). If you mix raw material streams, each stream must individually stay within the safety margin — averaging "good and bad" raw material works only statistically, and the auditor will ask for batch records.
Calorific value — a function of ash and moisture
NCV as received falls with moisture and ash. If you control these two parameters, the calorific value usually "takes care of itself" — but the declaration must be confirmed by calorimetric testing, not by calculation. A plant calorimeter or regular external testing is standard among certified producers.
Mechanical durability and density — the press and cooling
Durability ≥97.5% requires the right moisture of the material before the press (typically around 10–14% depending on the raw material), well-matched die compression and properly working rollers. Material that is too dry means brittle pellets; too wet means output drops and a cracking product. After the press the pellets are at 70–90 °C — too fast or uneven cooling generates microcracks that later turn into fines. Control durability with a durability tester (or a simplified method consistent with the documentation) on every shift.
Fines — screening and conveying
The 1% fines limit applies to the product as received. Even good pellets "regenerate" fines at every transfer — minimise the number of reloading steps and drop heights, and use an effective screen directly before bagging or bulk loading. Return screenings to the start of the process, not to the product.
Dimensions — die and knives
The diameter results from the die and is declared (6 or 8 mm); control it with a calliper or control sieves, because a worn die can "drift" within tolerance. You set the length with cutter knives — excess pellets above 40 mm is a frequent minor audit finding when knives are set incorrectly.
Chlorides and sulphur — chemical purity of the raw material
Cl ≤0.02% and S ≤0.04% in practice exclude raw materials from wood recycling (paints, glues, preservatives) and some agro biomass. Test these parameters when qualifying a new supplier and periodically in an accredited laboratory. A rise in chlorides is often the first signal that wood from windows, furniture or lacquered pallets has entered the stream.
Where errors arise: a process map
- Raw material — ash, chlorides, sulphur, nitrogen, heavy metals: you acquire the error with the purchase; the rescue is supplier qualification and incoming testing, not control at the end of the line;
- Drying — under- or over-drying spoils the moisture of the material for pressing and indirectly durability and NCV; the key is a working moisture measurement at the dryer outlet;
- Press — durability, bulk density, dimensions: a worn die, wrongly chosen compression, overheating of the material; keep a register of die replacements and operating parameters;
- Cooling — pellet microcracks and condensation of vapour inside the silo; watch the product temperature after the cooler (indicatively up to about +5 °C relative to ambient);
- Screening and internal transport — fines: a faulty sieve, excessive transfer heights, damaged screw conveyors grinding the pellets.
Testing frequency
You describe the testing scheme in the plant specification and that is what is audited. Practice compliant with the scheme requirements looks indicatively like this:
- Process tests (in-house) — moisture, durability, fines, dimensions: on every production shift or per batch, recorded in the register;
- Extended in-house tests — ash, NCV: regularly, indicatively once a week for bulk production or per declared volume, using methods from the EN ISO 18122/18125 series of standards;
- External confirmation tests — the full scope of parameters in an accredited laboratory: at certification, at the annual inspection and whenever nonconformity is suspected;
- Chloride, sulphur, nitrogen and metal tests — when qualifying a new raw material source and periodically, according to the raw material risk described in the specification.
Treat the frequencies as indicative — you will find the current requirements in the ENplus handbook and in your approved plant specification.
Working with an accredited laboratory
Choose a laboratory accredited to ISO/IEC 17025 in the scope of solid fuel testing methods (combustion, calorimetry, sieving, elemental analysis). Agree in the contract: the sampling method (preferably in line with EN ISO 18135, samples taken by a trained person), labelling the sample with the batch number, the turnaround time and the result format with units and measurement uncertainty. Archive results linked to the production batch — the auditor follows the chain: production record → batch number → test result → sales document. Inconsistent dates or missing links are a classic documentation nonconformity.
If you use several laboratories (e.g. because of deadlines), periodically compare their results on split samples — this is a good argument for the credibility of measurement supervision.
Actions in case of exceedances
The nonconforming product procedure should describe step by step:
- Stop the batch — physical marking/isolation of the storage location, blocking release in the records;
- Repeat the test on an enlarged sample — a single borderline result requires confirmation;
- Assess the extent of the problem — does it concern one batch, the whole shift, or the entire raw material stream from a given supplier;
- Decide — reclassification to a lower class (e.g. A2 if the limits are met), re-pelleting, withdrawal from the market as a certified product;
- Notify the customer if the nonconforming product has already left the plant — this is a scheme requirement, and avoiding the subject is a critical nonconformity;
- Launch corrective action — root cause analysis (raw material? die? dryer?) and a record of actions preventing recurrence.
Good handling of an exceedance is an asset at the audit — it shows that the system works. Hiding nonconformities is far worse than the nonconformity itself.
Frequently asked questions
Author: Michał Cierpiałowski
Lead auditor for sustainability certification systems. For over 16 years he has been preparing pellet and biomass producers for ENplus, DINplus, SURE, KZR INiG and FSC certification — from gap analysis to support during the certification audit.
LinkedIn profile